Clean Power Hydrogen pinpoints likely causes of electrolyser failure

X The Business Desk

Register for free to receive latest news stories direct to your inbox

Register

Clean Power Hydrogen (CPH2) has identified the likely causes of a testing failure involving its 1MW membrane-free electrolyser, with remedial design work now under way.

The AIM-listed group said an extensive internal investigation into the incident on 28 May 2026 had identified several factors which, in combination, were considered highly likely to have caused the failure.

However, no single definitive ignition source has been established, and aspects of the findings remain subject to independent verification by specialist experts.

The incident occurred during the third and final stage of factory acceptance testing of the MFE220 electrolyser.

CPH2 said the investigation had found no evidence that the incident originated within its proprietary membrane-free stacks or associated separator vessels.

Instead, the provisional findings point to a combination of factors including gas velocity and particle impingement near a valve, which may have generated sufficient energy to trigger ignition during controlled venting.

The specification and configuration of certain check valves, hoses and pipework bends are also under scrutiny.

Investigators are examining whether supplier quality and the exposed outdoor testing facility contributed to contamination within the system, alongside the applicability of European Industrial Gases Association guidance to the company’s technology and design.

The findings mean changes will be required to component designs, system-cleanliness procedures, manufacturing controls and monitoring of operating conditions before testing can be successfully completed.

The company has started remedial research, redesign and testing. Subject to satisfactory results and board approval of the final investigation conclusions, it intends to provide a revised design package to relevant licensees and prospective manufacturing partners.

The update comes as CPH2 pursues a strategic shift towards a capital-light technology development and licensing model, rather than manufacturing completed electrolysers itself.

It is also progressing discussions with Lisheen H2 Energy Park, known as Hidrigin, over a broader strategic partnership and manufacturing and technology development agreement.

In June, CPH2 announced a binding term sheet for a proposed £750,500 secured convertible loan note with Hidrigin, subject to conditions and definitive documentation.

However, following an oversubscribed fundraising, the parties agreed not to proceed with the loan note. CPH2 has repaid a £750,500 interim payment previously received under a legacy MFE220 sales contract, and confirmed that no loan note has been issued and no security granted.

Hidrigin’s technology licence is being extended to include rights for its own use in the United States. Discussions covering the US, Canada, Mexico and the UK remain ongoing, with no guarantee that a definitive agreement will be reached.

Chief executive Richard Scott said the investigation had reached an important milestone, allowing the company to identify the most likely causes and begin work on the necessary changes.

He said the findings continued to support the conclusion that there was no evidence the incident had originated within the company’s proprietary electrolyser stacks or separator vessels.

Independent verification remains under way, with CPH2 saying an improved technology roadmap would be communicated to the market in due course as part of its discussions with prospective strategic manufacturing partners.

Click here to sign up to receive our new South West business news...